Sign In | Join Free | My howtoaddlikebutton.com
China Xi'an Kacise Optronics Co.,Ltd. logo
Xi'an Kacise Optronics Co.,Ltd.
Kacise, understanding your automation needs.
Verified Supplier

7 Years

Home > Ultrasonic Flow Meter >

Ultrasonic Doppler Flowmeter for Accurate Fluid Velocity Measurement in Flood Monitoring and Sewage Discharge

Xi'an Kacise Optronics Co.,Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Ultrasonic Doppler Flowmeter for Accurate Fluid Velocity Measurement in Flood Monitoring and Sewage Discharge

Brand Name : Kacise

Model Number : KDF1300

Certification : certificate of explosion-proof, CE

Place of Origin : China (Mainland)

MOQ : 1pcs

Payment Terms : T/T, Western Union, MoneyGram

Supply Ability : 1000 Pieces per Week

Delivery Time : 5-8 working days

Packaging Details : each unit has individual box and all boxes are packed in standard packages or customers requests available

Power supply range : 10.8VDC~26.4VDC

12V power consumption : 45mA±1mA (about 0.54W)

24V power consumption : 26mA±1mA (about 0.62W

Flow rate accuracy : ± 1%

Water depth accuracy : ±3cm

Flow rate resolution : 1mm/s

Temperature resolution : 0.1℃

Water depth resolution : 1mm

Material : POM

Weight : 2.6±0.1kg

Protection level : IP68

Contact Now

KDF1300 Ultrasonic Doppler Flowmeter

1.Introduction

The ultrasonic Doppler flowmeter is based on the Doppler effect. The probe sends out a beam of ultrasonic waves obliquely upward. The ultrasonic waves propagate in the fluid. The fluid may contain impurities such as bubbles or particles (it can be considered that the impurities in the fluid have the same speed as the water flow). When the ultrasonic waves come into contact with the impurities in the fluid, the reflected ultrasonic waves will produce a Doppler frequency shift Δf. The Doppler frequency shift Δf is proportional to the flow velocity. The flow velocity of the fluid can be measured by measuring the Doppler frequency shift Δf.

2.Technical Specifications

Power Supply

Power supply range: 10.8VDC~26.4VDC;

12V power consumption: 45mA±1mA (about 0.54W)

24V power consumption: 26mA±1mA (about 0.62W)

Output Characteristics RS485/ModBus standard protocol
Measurement Performance

Flow rate range: ±0.03m/s~±5m/s (customizable ±0.03m/s~±10m/s);

Water depth range: 0.02~3m, 0.02~10m (please confirm the maximum water depth before ordering);

Flow rate accuracy: ± 1% ;

Flow rate accuracy: ±1~3% (measurement accuracy varies due to the on-site working environment);

Water depth accuracy: ±3cm;

Flow rate resolution: 1mm/s;

Temperature resolution: 0.1℃;

Water depth resolution: 1mm

Physical Properties

Material: POM;

Weight: 2.6±0.1kg;

Protection level: IP68;

Cable: 4-core shielded cable with air guide tube, factory default length 10 meters, wire diameter 8mm (other wire lengths need to be customized).

Working Environment

Working temperature: 0~60℃ (non-freezing state);

Storage temperature: -20~80℃;

Sand content: <20g/L;

Acidity: pH value is between 6 and 8.

3.Dimensions

3.1 Product picture

Ultrasonic Doppler Flowmeter for Accurate Fluid Velocity Measurement in Flood Monitoring and Sewage Discharge

3.2 Structural dimensions

Ultrasonic Doppler Flowmeter for Accurate Fluid Velocity Measurement in Flood Monitoring and Sewage DischargeUltrasonic Doppler Flowmeter for Accurate Fluid Velocity Measurement in Flood Monitoring and Sewage Discharge

4.Application

An ultrasonic Doppler flowmeter is a device used to measure water flow rates in pipes, channels, or rivers. It is primarily utilized in several key areas, including:

  • Flood disaster monitoring
  • Sewage discharge measurement
  • Monitoring of natural rivers
  • Municipal water supply and drainage systems
  • Water loss and infiltration tracking
  • Irrigation process control
  • Estuary and tidal studies
  • Fisheries and water conservancy
  • Coastal erosion research
  • Culvert flow monitoring
  • Road drainage assessment
  • Canal flow studies
  • River process monitoring

5.Wiring

Power wire:

Red wire connected to the positive pole of the power supply (12V+ or 24V+);

Green wire connected to the negative pole of the power supply (12V- or 24V-);

Signal wire:

White wire connected to RS485A (T/R+);

Yellow wire connected to RS485B (T/R-);

Transparent air duct:

Must be kept unobstructed with the atmosphere, and pay attention to protection during installation, especially when passing through the threading tube, it is necessary to protect it with tape before threading to avoid water ingress. If water ingress occurs, it may cause water depth errors and other phenomena.

The transparent air duct cannot be folded, and the bending angle cannot be ﹤90° when threading the tube.


Product Tags:

Flood Monitoring Ultrasonic Doppler Flowmeter

      

Accurate Fluid Velocity Ultrasonic Doppler Flowmeter

      

Sewage Discharge Ultrasonic Doppler Flowmeter

      
Wholesale Ultrasonic Doppler Flowmeter for Accurate Fluid Velocity Measurement in Flood Monitoring and Sewage Discharge from china suppliers

Ultrasonic Doppler Flowmeter for Accurate Fluid Velocity Measurement in Flood Monitoring and Sewage Discharge Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Xi'an Kacise Optronics Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0