Sign In | Join Free | My howtoaddlikebutton.com |
|
Brand Name : KACISE
Model Number : KGD-MQ-503
Certification : CE
Place of Origin : CHINA
MOQ : 1PCS
Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability : 1000 Piece/Pieces per Week negotiable
Delivery Time : 5-8 work days
Packaging Details : each unit has individual box and all boxes are packed in standard packages or customers requests available
Measured Components : H₂S, O₂, CO, CO₂, CH₄
Measurement Principle : TDLAS
Accuracy : ≤ ±1%F.S.
Repeatability : ≤ ±1%
Span Drift : ≤ ±1%F.S.
Resolution : 0.01%VOL
Extractive Laser Gas Analysis System KGD - MQ - 503
Product Introduction
This system is designed for working conditions with high dust content in the sample gas. It consists of four parts: a sampling probe, a pretreatment unit, a control unit, and a gas analysis unit. The system adopts a transmissive design based on Tunable Diode Laser Absorption Spectroscopy (TDLAS) technology, which can continuously and real - time reflect the concentration of the measured gas. This is beneficial for improving the utilization efficiency of gas, saving energy and reducing consumption, and ensuring safe production in industrial sites.
Product Features
Technical Parameters
Items | Details |
Measured Components | H₂S, O₂, CO, CO₂, CH₄ |
Measurement Principle | TDLAS |
Test Range | H₂S: 0 - 100ppm, 0 - 5000ppm |
O₂: (0 - 5) %VOL (Can be customized to 100%) | |
CO: (0 - 100) %VOL | |
CO₂: (0 - 100) %VOL | |
CH₄: (0 - 20) %VOL | |
Accuracy | ≤ ±1%F.S. |
Repeatability | ≤ ±1% |
Span Drift | ≤ ±1%F.S. |
Resolution | 0.01%VOL |
Operating Parameters | |
Explosion - proof Grade | Ex db IIC T6 Gb / Ex tb IIIC T80℃ Db |
Ambient Temperature | (-20 - +60)℃ |
Operating Power Supply | 220V AC, 50Hz |
Operating Gas | (0.3 - 0.8) MPa Industrial Nitrogen |
Interface Signal | |
Communication | RS485, RS232 |
Output Mode | 2 - way 4 - 20mA output |
3 - way relay output |
![]() |
Extractive Laser Gas Analysis System KGD - MQ - 503 Images |